Home >> Products>Products by Category>Thermal Cyclers & Real-Time PCR System>Real-Time PCR System 6 Channel ITR-6000(240V/60Hz)
Catalogue number : 6207005-02
Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder.
Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder. Designed with 3×48×0.2 ml (5 to 100 µl) capacity and 100 to 1010 test dynamic range. Rapidly set up runs and monitor amplification traces in real time on integrated LCD touch screen. Freshly designed automatic hot-lid without manual operation ensures constant pressure for various tube heights.
| Product Type | ITR-6000 |
| Temperature Range (℃) | 4-100℃ |
| Ramp Rate | ≥ 6.5°C/s |
| Selectable Heated Lid Temperature | 30 to 110°C |
| Sample Volume | 5-100μl |
| Dynamic Range | 100-1010 |
| Sensitivity (detection threshold) | 1 Copy |
| Temperature Uniformity | ±0.1 °C |
| Additional Dyes | F1: FAM, SYBR, GREEN, F2: VIC, HEX, JOE, TET, YELLOW, F3: CY3, F4: ROX, F5: CY5, F6:, CY5.5, F7: Reserved , F8: Reserved |
| Software | Windows vista/7/8/10 |
| Sample Capacity (0.2ml) | 3×48×0.2 ml(5 to 100 µl):48, 96 and 144(optional) |
| Data Transfer | USB 2.0 |
| Dimensions L x W x H (mm) | 586×525×780 mm |
| Electrical Requirements | 240V/60Hz |
| Catalogue No. | 6207005-02 |
|
Model |
ITR-6000 |
|
|
Capacity |
3×48×0.2 ml(5 to 100 µl):48, 96 and 144(optional) |
|
|
Reaction Volume |
5 to 100 µl |
|
|
Display |
LED |
|
|
Temperature Range |
4 to 100°C |
|
|
Uniformity |
±0.1°C |
|
|
Temperature Control |
±0.1°c |
|
|
Detector |
Photoelectric sensor |
|
|
Sensitivity |
1 copy |
|
|
Test Dynamic Range |
100 to 1010 |
|
|
Fluorescent Dye |
F1: FAM, SYBR, GREEN, F2: VIC, HEX, JOE, TET, YELLOW, F3: CY3, F4: ROX, F5: CY5, F6:, CY5.5, F7: Reserved , F8: Reserved |
|
|
Channel |
8 |
|
|
Ramp up Rate |
≥ 6.5°C/s |
|
|
Ramp down Rate |
≥ 6.5°C/s |
|
|
Hot Lid |
Automatic |
|
|
Hot Lid Temperature |
30 to 110°C |
|
|
Sample Linearity |
Linear regression coefficient r≥0.999 |
|
|
Fluorescent Intensity Detection |
CV≤0.5% |
|
|
Temperature Control Pattern |
Semi-conductor TE module |
|
|
Operating System |
Windows vista/7/8/10 |
|
|
Connectivity |
USB 2.0 |
|
|
Overall Dimensions |
586×525×780 mm |
|
|
Weight |
|
|
|
Electrical Requirements |
100 to 240V, 50/60Hz, 500 to 1500 VA |
|
|
Catalogue No. |
6207005-01 |
6207005-02 |