Adding your first favourite item.
Home >> Products>Products by Category>Colour & Appearance Testing Instruments>Reflectance-Transmittance-Spectrophotometer>Reflectance Spectrophotometer IRS-1000 Series
Reflectance Spectrophotometer IRS-1000 Series using a 2° or 10° viewing angle, 2° is used for viewing angles of 1 to 4; whereas 10° is used for viewing angles of more than 4. Reflectance spectrophotometer used d/8° geometry of sphere measurement diffused illumination integrating systems illuminate an object equally from all directions or angles ...
Reflectance Spectrophotometer IRS-1000 Series using a 2° or 10° viewing angle, 2° is used for viewing angles of 1 to 4; whereas 10° is used for viewing angles of more than 4. Reflectance spectrophotometer used d/8° geometry of sphere measurement diffused illumination integrating systems illuminate an object equally from all directions or angles and detects the reflected light at 8°. The applications including plastic, electronic, painting, coating, ink, textile, garment, printing and dyeing, food, medical, cosmetic, industries, research and development, and laboratories. Also, measure the reflectance spectrum and another color index precisely and control product quality management correctly. ISO and CIE recommended and equipped with a combined LED light sources with flat grating spectrophotometric mode. The IRS-1000 is used to measure specular component excluded (SCE) or specular component included (SCI) mode.
Accessories
Optional Accessories
Model |
IRS-1301 |
IRS-1302
|
IRS-1303 |
Wavelength |
400 to 700 nm
|
||
Geometry |
d/8 (diffused illumination, 8°viewing angle) |
Reflect: di:8°, de:8°(diffused illumination, 8°viewing angle);SCI /SCE
|
Reflect: di:8°, de:8°(diffused illumination, 8°viewing angle)SCI/SCE
|
Illuminant |
D65,A, C, D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5)F11(TL84), F12(TL83/U30) |
D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30) |
D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) |
Spectrophotometric Mode |
- |
Flat Grating
|
|
Display |
3.5-inch TFT color LCD, Capacitive Touch Screen
|
||
Detector |
Silicon photodiode array (double row 40 groups)
|
||
Repeatability |
Spectral Reflectance: standard deviation within 0.1 %(400~700nm: within 0.2%) Colorimetric Value: Standard deviation within ΔE*ab 0.04 (Measurement conditions: white calibration plate measured 30 times at 5 seconds intervals after white calibration |
Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Wavelength Interval |
10nm
|
||
Display Data |
Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation, color index setting(ΔE*94, ΔE*cmc, ΔE2000), tolerance prompt, reverse prompt, time setting, language setting, restore factory setting |
|
Operating Temperature |
|
0 to 40℃
|
|
Storage Temperature |
-20 to 50℃
|
||
Source |
Combined LED sources |
LED light source
|
|
Index |
WI(ASTM E313,CIE/ISO,AATCC), YI(ASTM, D1925,ASTM 313),TI(ASTM E313,CIE/ISO), Metamerism Index (Mt), Strength, Color Stain, Color Fastness |
WI(ASTM E313,CIE/ISO,AATCC, YI(ASTM D1925,ASTM 313), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, |
WI(ASTM E313,CIE/ISO,AATCC), YI(ASTM, D1925,ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness |
Color Difference |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*cmc(l:c),CIE2000ΔE*00,ΔE(h) |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 |
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Color Space |
|
CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,Munsell(C/2) |
|
Reflectance Range |
0-200%
|
||
Observer |
2°/10°
|
||
Battery |
Li-ion battery. 2800 times within 8 hours. |
3.7V,5000mAh Li-ion battery, 6000 measurements within 8 hours |
3.7V,5000mAh Li-ion battery, 6000 measurements within 8 hours |
Humidity |
0 to 85%RH
|
||
Interface |
USB/RS-232 |
USB
|
USB, Bluetooth 4.2 |
Storage |
1000 Standards, 15000 Samples |
Standard 1000 Pcs, Sample 20000 Pcs
|
Standard 1000 Pcs, Sample 30000 Pcs |
Dimensions |
90x77x230mm |
129X76X217mm
|
|
Weight |
Approx 600g
|
||
Catalogue No. |
1501505-04
|
1501510-04
|
1501515-04
|
* Required fields
Catalogue No. | Image | Product Detail | Availability | Price (Excludes VAT) |
|
---|---|---|---|---|---|
1501505-04 |
Reflectance Spectrophotometer IRS-1301 Reflectance Spectrophotometer IRS-1301 using a 2° or 10° viewing angle, 2° is used for viewing angles of 1 to 4; whereas 10° is used for... |
3-4 Weeks |
|||
1501510-04 |
Reflectance Spectrophotometer IRS-1302 Reflectance Spectrophotometer IRS-1302 using a 2° or 10° viewing angle, 2° is used for viewing angles of 1 to 4; whereas 10° is used for... |
3-4 Weeks |
$6,950.00 |
||
1501515-04 |
Reflectance Spectrophotometer IRS-1303 Reflectance Spectrophotometer IRS-1303 using a 2° or 10° viewing angle, 2° is used for viewing angles of 1 to 4; whereas 10° is used for... |
3-4 Weeks |
$9,740.00 |